• Rapid test Supplier
  • SARSCoV2 Neutralizing Antibody Test Kit China Suppliers and Factory

SARSCoV2 Neutralizing Antibody Test Kit China Suppliers and Factory

High-precision Anti-SARS-COV-2 Neutralizing Antibody Test for in vitro qualitative detection in human serum or plasma. Sourced from a leading China factory, our kits identify antibodies blocking the RBD-ACE2 interaction. Reliable diagnostic solutions from trusted China suppliers.

Details

Tags

The GOLDEN TIME COVID-19 (SARS-CoV-2) Neutralizing Antibody Test Kit is a professional-grade diagnostic tool designed for the qualitative detection of neutralizing antibodies against SARS-CoV-2. Utilizing advanced lateral flow assay technology and a competitive inhibition principle, this kit provides a reliable method for identifying the presence of neutralizing antibodies in human serum or plasma specimens, essential for evaluating immune responses.

Engineered for high precision and clinical reliability, the test ensures exceptional diagnostic accuracy with 100% clinical specificity. This makes it an indispensable asset for medical institutions and laboratories requiring rapid, accurate, and standardized screening of SARS-CoV-2 neutralizing antibodies to support clinical decision-making and public health monitoring.

Detailed Parameters

Product NameCOVID-19 (SARS-CoV-2) Neutralizing Antibody Test Kit Brand NameGOLDEN TIME
MethodologyColloidal gold (Lateral Flow Assay) Specimen TypeWhole blood, serum, or plasma
Clinical Sensitivity94.6% Clinical Specificity100%
Reading Time15 minutes Storage Temp2℃ ~ 30℃ (Dry place, avoid sunlight)
Shelf Life18 months from manufacturing date Packing Options1/5/20 tests/carton (Customizable)

Key Advantages

High Specificity

Achieves 100% clinical specificity, minimizing false positive results for absolute diagnostic confidence.

Rapid Results

Delivers clear and accurate diagnostic readings within just 15 minutes of application.

Proven Sensitivity

A high clinical sensitivity of 94.6% ensures a low rate of false negatives in patient screening.

User-Friendly Design

Intuitive lateral flow format requires minimal training for healthcare professionals to execute.

Versatile Sampling

Compatible with whole blood, serum, and plasma, providing flexibility in various clinical settings.

Stable Storage

Long-term stability for 18 months with standard storage requirements (2℃-30℃).

Product Gallery

Management Platforms

Inventory Control

Flexible packaging (1/5/20 tests) allows for efficient stock management across different facility sizes.

Quality Assurance

Strict adherence to manufacturing standards ensures batch-to-batch consistency and reliability.

Rapid Deployment

Easy-to-use kits allow for immediate large-scale screening during peak healthcare demands.

Cold Chain Logistics

Optimized for 2℃ to 30℃ storage, simplifying the logistics and transport chain.

Full Kit Integration

Each kit includes dilution buffers and pipettes, reducing the need for external consumables.

Clinical Validation

Validated methodology providing reliable data for epidemiological and clinical research.

Investment Return Comparison

MetricStandard Lab Test (ELISA)GOLDEN TIME Rapid Test
Turnaround Time24-72 Hours15 Minutes
Operational CostHigh (Equipment/Labor)Low (Point-of-Care)
Technical RequirementSpecialized Lab StaffGeneral Healthcare Staff
Specificity RateVariable100% Clinical Specificity
Testing ThroughputBatch ProcessingInstant Individual Testing

Frequently Asked Questions

Q: What is the difference between a neutralizing antibody test and a general antibody test?

A neutralizing antibody test specifically detects antibodies that can block the virus from entering cells, which is a more direct indicator of protective immunity than general antibody tests.

Q: Can this test be used with whole blood samples?

Yes, the GOLDEN TIME kit is designed to be compatible with whole blood, serum, or plasma specimens.

Q: How should the test kits be stored to maintain stability?

Kits should be stored in a dry place between 2℃ and 30℃, avoiding direct sunlight. Do not freeze the products.

Q: What is the shelf life of the Neutralizing Antibody Test Kit?

The product is valid for 18 months from the date of manufacturing, provided it is stored under the recommended conditions.

Q: How soon must the test be used after opening the foil bag?

Once the aluminum foil bag is unsealed, the test card should be used as soon as possible, ideally within one hour.

Q: Is the packaging customizable for large medical distributors?

Yes, we offer flexible packing options including 1, 5, or 20 tests per carton, and can customize according to specific customer requirements.

Get a Professional Quote for SARS-CoV-2 Diagnostic Solutions

Contact Us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.